• Home
  • About Caledonian
  • News
  • Products
  • Applications
  • Technical Information Testing Authorities | Testing Equipment Manufacturers | Magazines | Organizations | Caledonian Corporater Website
  • Download
  • Sitemap
  • Contacts
  • Chinese

Caledonian Airport Cables

  • Airport Lighting Power Cables
  • Airport Series Runway Lighting Cables
  • Airport Lighting Fire Resistant Cables
  • Airport Lighting Flame Retardant Cables
  • FAS (Fire Alarm System)

  • Detector Cable
  • Fire Communication Cable
  • Sounder Cable
  • Control Cable
  • RS485 Data Cable

SACS (Security Access Control System)

  • RS485 Data Cables
  • Push Button Cables
  • Lock Cables
  • Card Reader Cables

CCTV (Closed Circuit TV)

  • Video Cables
  • RS485 Data Cables

PAS (Public Address System)

  • Loudspeaker Cables
  • RS485 Data Cables

BMS (Building Management System)

  • Digital Signal Cables
  • Analog Signal Cables
  • RS485 Data Cables
  • Temperature Control Cables

CPMS (Car Park Management System)

  • Communication Cables
  • Talk-back Cables

Baggage Handling System Cables

Caledonian Airport Cables

PAS (Public Address System)

RS485 Data Cable RE-02Y(St)H 1P18A

RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

Fire Alarm System RS485 Data Cable RE-02Y(St)H 1P18ARS 485 Data Cable

APPLICATIONS

The cables are designed for RS485 data connections. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

STANDARDS

Basic design EIA/TIA 485
Halogen Free IEC 60754-1
No corrosive gas emission IEC 60754-2
Minimum Smoke Emission IEC 61034-1/2
Reduced Fire Propagation IEC 60332-3C /NF C 32070-2.2 (C1)
Flame Retardance IEC 60332-1 / NF C 32-070-2.1 (C2)
Fire Resistance IEC 60331-23 / NF C 32-070-2.3(CR1)

CABLE CONSTRUCTION

Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5.
Insulation: Solid or foam PE compound
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.
Overall screen: Aluminum/ polyester tape with tinned copper drain wire.
Fire Barrier: Fireproof Tape.
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

ElECTRICAL PROPERTIES

Dielectric test 1000 V r.m.s. for 5’ (core-core)
  1000 V r.m.s. for 5’ (core-screen)
Impedance 120Ω
Capacitance 45 nF/km conductor to conductor
  90 nF/km conductor to shield

PHYSICAL AND THERMAL PROPERTIES

Temperature range during operation (fixed state): -30°C – +90°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 8 × Overall Diameter

CONSTRUCTION PARAMETERS

RE-02Y(ST)H 1P18A

No.of pair × Wire Gange Number & Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Approx.Weight
No AWG No/mm mm mm mm kg/km
1 18 7/0.404 0.65 0.8 8.2 80
1 18 16/0.254 0.65 0.8 8.2 80